| Home > Products > CLX Instrument |
| CLX OnLine Residual Chlorine Monitor |
User selectable features and innovative design sets the new CLX OnLine Residual Chlorine Monitor apart from the competition. Cycle times that are adjustable from 90 seconds to 10 minutes, 4-20mA and Modbus outputs that can control feed pumps and user settable alarms equates to low operating and maintenance costs. A new flow through design maintains cuvette cleanliness and allows for viewing of optical operations. The strong, shatterproof case that opens to facilitate reagent replacement also allows easy access to all service functions which reduces maintenance time. Unattended operation and low chemical usage equates to low operating cost. |
| |
|
| Standard Features |


|
| |
| Free or Total Chlorine |
| Can be used to measure Free or Total Chlorine - the only difference is the reagents |
| Low Operating Costs |
| Low Reagent use translates into low operating cost of pennies a day |
| User Selectable Cycle Times |
| Cycle times can vary between 90 seconds and 10 minutes |
| Colorimetric DPD Chemistry |
| Uses inexpensive DPD chemistry rather than expensive electrodes |
Simple Operation |
| Designed for unattended operation up to 30 days |
| Microprocessor Based Technology |
| Microprocessor based technology ensures high quality at the industry's lowest price |
Drinking Water, Wastewater and More |
| |
| Alarms |
| Two user selectable alarms for sample concentration |
|
| 4-20mA and RS-485 Modbus |
The CLX comes complete with an operating manual. |
| USEPA Accepted |
Reagents must be purchased separately. |
| Made in the USA |
|
| |
| Related Products |

|

|
| Chlorine Pocket Chlorine Photometer |
Chlorine Dioxide Pocket Photometer |
 |
|
| DPD Chlorine Reagent Dispenser |
|
| |
|
| Specifications: |
|
| Range |
0 - 10 mg/l |
| Cycle Time |
User Selectable: 90 seconds - 10 Minutes |
| Accuracy |
0-6 mg/l - ±5% or 0.03 mg/l of CL2 whichever is greater
6-10 mg/l - ±10% or 0.06 mg/l if CL2 whichever is greater |
| Resolution |
0.01 mg/l |
| Method |
USEPA accepted DPD method of analysis for measuring Free or Total Residual Chlorine |
| Standard Outputs |
4-20 mA and RS-485 with Modbus |
| User Alarms |
2 User Selectable Alarms for Sample Concentration |
| Operating Temperature |
5° - 40°C (41° to 104°F) |
| Input Pressure |
1 - 200psi |
| Enclosure |
ABS Plastic, Nema 4X, IP66 |
| Power |
100 - 240 Volt Auto Switchable 47 - 63hz |
| Certifications |
CE, UL, CSA,(ETL, ETLc) |
| Shipping Dimensions |
16" x 16" x 10" (41cm x 41cm x 26cm) |
| Shipping Weight |
8 lbs (3.6 kg) |
| |
|
| CLX Operators Manual |
|
| CLX Modbus Manual |
|
| CLX Full Specifications Document |
 |
| CLX Instrument and Accessories |
|
|
| |
|
| |