              Dissolved Ozone System Specifications

Connect this Dissolved Ozone sensor to a PLC for
seamless integration with industrial control
systems. Use any computer to display data,
calibrate and customize the measurement
without an intermediate analyzer electronics
box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down.
Save space, time and money.

• Clark Cell technology

• Pre-calibrated (no field calibration required)

• Plug & play sensor heads

• Rugged, foul resistant membrane

• Electrode protection options

• Simple membrane cartridge replacement

• Direct data reporting

• Plug & play industrial communications adapters

 

Measurement System Performance
Range: 0 to 40 ppm
Resolution: 0.01 ppm
Accuracy: 0.04 ppm
Step Response Time: 90% in 90 seconds
Note: Typical at 25°C
Performance unaffected by cable length
Units of Measure
Measurement Units: ppm, mg/l, %
Temperature Units: °C, °F
Operational Environment
                                        PEEK® Sensor Head
Temperature Range: -5°C to 50°C
Maximum Pressure: 150 psi @ 50°C
Maximum Flow Rate: 10 ft/second
Calibration
Air: Automatically adjusts for set pressure
Sample: 1 point
Zero: 1 point
Temperature: 1 and 2 point
Note: D.O. and temperature are precalibrated at the
           factory
Power Requirements
Voltage Range: 10 to 30 VDC
Maximum Power: 200 mW
Typical Power: 120 mW
Note: Class II DC power supply required

Approvals and Ratings                                                            Immunity & Emissions: CE (EN61326 and
                                             EN61326:1998)
Safety: CE (EN 61010-1) UL 508
Hazardous Locations: UL Class I, Division 2

Construction
Process Electrodes: Gold Cathode, Silver Anode,
                                       Silver Reference
                     (3 Electrode Polarographic Clark Cell)
Membrane: FEP Teflon
O-Rings: Viton® (other materials available)
Sensor Head Material: PEEK®
Other Configuration Options
Sensor Filter: 0 to 100 seconds
Temperature Filter: 0 to 100 seconds
   