Home > Products > Micro100 Instrument
Micro100 Laboratory Turbidimeter

Designed to provide the accuracy demanded by today's scientist, the Micro100 Laboratory Turbidimeter is ready to meet the challenge. Features like the Auto Alert Calibration Prompt and the Quick Connection Lamp Module, allow for simple calibration and low maintenance. With a resolution of 0.01 NTU at low turbidity readings and an extended range to 1,000 NTU, the Micro100 is an ideal and affordable tool for research as well as routine analytical measurements.

   
Standard Features Micro100 Turbidimeter
 
Auto Ranging 0 - 1000 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate measurement
Auto Alert Calibration Prompt
Automatically prompts the operator when calibration of the instrument is needed
Simple Calibration Procedures
Calibration initiated with the push of a button ensures accurate readings
RS-232 Output
Date, time, and NTU reading can be captured with a serial printer or data recorder
Made in the USA
 
OPTIONAL FEATURES:
 
Infrared Light Source (Micro100 IR)
Micro100 comes with a complete set of calibration standards (0.02, 10 and 1000 NTU), two measuring cuvettes with light shield caps, operator's manual and power supply.
Meets international standard ISO 7027 for turbidity measurement
Pour-through assembly
Save time by pouring your grab sample through the measurement chamber
Note: The Micro100 meets performance criteria specified by USEPA method 180.1 for NTU measurement and ISO7027 (IR version).
Reusable Calibration Standards
Quick and easy calibration across all ranges without the need to mix Formazin  
Related Products
Micro1000 laboratory turbidimeter MicroTPI TurbidimeterMicroTPW turbidimeter

Micro1000 Laboratory Turbidimeter

MicroTPI / TPW Handheld Turbidimeter

MicroTOL DRT-15CE Turbidimeter
MicroTOL OnLine Turbidimeter DRT-15CE Portable Turbidimeter
   
Specifications:  
Principal of Operation Nephelometric non-ratio
Range Auto ranging from 0 - 1000 NTU
Accuracy ± 2% of reading plus 0.01 NTU
Resolution

0.01 NTU (0 - 9.99 NTU)

0.1 NTU (10 - 99.9 NTU)

1 NTU (100 - 1000 NTU)

Response Time < 6 seconds
Sample Size 30 ml (27ml minimum
Light Source Quick connect Tungsten Filament or Infrared Operating
Temperature 32° - 122°F (0° - 50°C)
Outputs RS-232 Serial Port
Dimensions 10.75 x 10 x 3.75 inches (27.3 x 25.4 x 9.5 cm)
Weight 2.9 lbs. (1.32 kg)
Safety rating UL, CSA, CE
Micro100 Operator's Manual
Micro100 Specification Literature
Adobe Reader download
Micro100 Instrument and Accessories

 

 

 