Products

CLX-XT Extended Reagent Life Residual Chlorine Monitor for Ballast Water

CLX-XT Extended Reagent Life Residual Chlorine Monitor for Ballast Water
view image

CLX-XT Extended Reagent Life Chlorine Monitor is an economical and low maintenance instrument for shipboard ballast water, potable water or wastewater applications that require continuous monitoring and control of residual Total Chlorine levels. User selectable cycle times, 4-20mA and RS-485 with Modbus output that can be used to control feed pumps and user selectable alarms allow complete manual or automatic control of chlorine dosing. The instrument is housed in a strong, shatterproof IP66 case (except fan - IP54) with easy access to all service functions and reagents.

Optimized for high temperature marine applications

Use in areas of high ambient temperatures up to 55°C (131°F)

Total Chlorine

Low operating costs

Simple operation

Designed for unattended operation up to 90 days (depending on cycle time)

Colorimetric DPD method

Variable cycle times

Cycle times can vary between 110 seconds to 10 minutes (optional 60 seconds to 10 minutes)

Alarms

Two user selectable alarms for sample concentration

Ballast water treatment, drinking water, wastewater and more

4-20mA and RS-485 with Modbus

USEPA accepted method

Certified to: Lloyds Register Test Specification for Vibration and 22 Degree Tilt Test EN 60954: 2002 Section 8.2, 8.4, 8.7, Specification test N01: Section 14

NEW - Extended range to 15ppm (option) ± 10% accuracy

Made in the USA

Range 0 - 10 mg/l
Cycle time User selectable: 110 seconds - 10 minutes
Optional; 60 seconds - 10 minutes
Accuracy 0 - 6 mg/l - ±5% or 0.03 mg/l of CL2 whichever is greater
6 - 10 mg/l - ±10%
Resolution 0.01 mg/l
Method USEPA accepted DPD method of analysis for measuring Total Residual Chlorine
Standard outputs 4-20 mA and RS-485 with Modbus
User alarms 2 user selectable alarms for sample concentration
Operating temperature 0° - 55°C (32° to 131°F)
Input pressure 0.3 bar - 10.3 bar (5 - 150psi)
Enclosure IP66 (except fan IP54)
Power 100 - 240 VAC auto switchable 47-63hz
Certifications CE, UL, CSA, (ETL, ETLc)
Flow rate to waste 200 - 400 ml/min
Installed dimensions 15.7" x 18.3" x 8.5" (40cm x 46.5cm x 21.6cm)

Instruments

Model Description
28030 CLX-XT Extended Reagent Life Chlorine Monitor - for Total Chlorine complete with operator's manual. Reagents must be purchased separately.

Accessories

Model Description
09991 Total Chlorine reagent kit for CLX-XT and CLX-Ex 12 month supply (based on estimated BWTS operational cycles)
25018S Flow through cuvette (CLX)
28040 Replacement tubing/cuvette kit (CLX-XT)

Service & Repairs

Please request a Return Material Authorization(RMA) number before sending an instrument in for repair.

Send a Request »

Where to Buy

Enter your zipcode to find your local HF Scientific sales rep.

International Listings »